
Performance Energy
Performance Energy
We pride our company on reliability, great communication, integrity and quality work. We are experts in air sealing & insulation and will do our best to keep you as educated as we can on your particular task or project. We look forward to earning your business!
"Levi understood our wanting a Thermal Imaging & Blower Door, Energy Audit Tests performed regardless NewCon 10mo old because of 2 floods 2nd wk found 1/3 of 3000sqft -0- insulation. Then 3rd major flood 3rd wk and 10mo later still trying to resolve because of tow the co line "denied" work tickets to bring house to 2023 code. Blower Door Test results: 39-qty of the can lighting are NOT sealed NOR are 40-qty Outside Wall Sockets sealed (=Winter heat escapes into Attic/Outside Siding and =Summer 180 degree Attic heat penetrates into the house. Thermal Imaging results: all 3 tray ceilings JOISTS are visible from inside and all Corners of Ceiling & Corner Exterior Walls (= missing -0- to a "dusting" of insulation attic/exterior walls) Levi found a 30ft long x ~6" wide open cut center back roof covered in tar paper & single shingles for length -0- RidgeVent -0- support during storm. We called the State & the County! House should never have passed for CO. We highly recommend PE !"
USN G on March 2024
We pride our company on reliability, great communication, integrity and quality work. We are experts in air sealing & insulation and will do our best to keep you as educated as we can on your particular task or project. We look forward to earning your business!
"Levi understood our wanting a Thermal Imaging & Blower Door, Energy Audit Tests performed regardless NewCon 10mo old because of 2 floods 2nd wk found 1/3 of 3000sqft -0- insulation. Then 3rd major flood 3rd wk and 10mo later still trying to resolve because of tow the co line "denied" work tickets to bring house to 2023 code. Blower Door Test results: 39-qty of the can lighting are NOT sealed NOR are 40-qty Outside Wall Sockets sealed (=Winter heat escapes into Attic/Outside Siding and =Summer 180 degree Attic heat penetrates into the house. Thermal Imaging results: all 3 tray ceilings JOISTS are visible from inside and all Corners of Ceiling & Corner Exterior Walls (= missing -0- to a "dusting" of insulation attic/exterior walls) Levi found a 30ft long x ~6" wide open cut center back roof covered in tar paper & single shingles for length -0- RidgeVent -0- support during storm. We called the State & the County! House should never have passed for CO. We highly recommend PE !"
USN G on March 2024